background image

15

Maintenance (Continued)

rePlaCeMeNt PartS

Use only genuine

Campbell Hausfeld

service parts. Tool performance, safety and
durability could be reduced if improper parts
are used. When ordering replacement parts,
specify by part number.

aSSeMbly ProCedure For SealS
When repairing a nailer, the internal parts
must be cleaned and lubricated. Parker
O-lube or equivalent must be used on
all o-rings. Each o-ring must be coated
with O-lube before assembling. A small
amount of oil must be used on all moving

CHN50300

www.chpower.com

Troubleshooting Guide

SYMPTOM

CAUSe

SOLUTION

Lack of power; slow to cycle.

1. Tool is too dry

1. Add lubricant

2. Air pressure is low

2. Check air supply equipment

3. Exhaust is blocked

3. Clean exhaust

Shooting no fastener or
intermittent feeding

1. Damaged pusher spring

1. Replace spring

2. Wrong size fastener is being used

2. Use standard fasteners

3. Magazine or wear plate is dirty

3. Clean magazine and nose

Fastener jammed in tool

1. Driver channel is worn

1. Replace wear plate

2. Driver is broken or worn

2. Replace driver

3. Fasteners are bent

3. Use standard fasteners

Stop using nailer immediately if any of the following problems occur. Serious personal injury could result.

Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.

surfaces and pivots. After reassembling,
a few drops of 30W non-detergent oil or
equivalent, must be added through the air
line before testing.

teCHNICal ServICe
For information regarding the operation
or repair of this product, please call
1-800-543-6400.

Advertising