Connection the Double Oven Mains Cable

Important!
This oven must be connected to the mains power supply only by a suitably qualified person.

Unscrew the screw A securing the cover plate B behind the oven (fig. 40).
– Remove the cover plate B.
– Remove the screws C from the cable clamp (fig. 41).
– Insert the mains cable (type H05RR-F or H05VV-F - 3x4 mm

2

section) into the cable protector P.

– Connect the phase and earth cables to the mains terminal connection block D.

EARTH

N

NEUTRAL

L

LIVE

– Refit the cable clamp so that it clamps the outer sleeving of the cable, and screw the screws C.
– Refit the cover plate B and fix it with the screw A.

WARNING: This appliance must be earthed

Green & Yellow
(Earth)

Brown (Live)

Blue (Neutral)

N

L

A

C

P

D

B

Fig. 40

Fig. 41