Operation, Stardance direct vent/natural vent gas heater – Vermont Casting Stardance SDV30 User Manual

Page 23

Advertising
background image

23

Stardance Direct Vent/Natural Vent Gas Heater

20007065

Operation

The Stardance is operated with the operable door front
plate in place with the doors open or closed. To open
the front doors, insert the handle into the door latch stub
and turn it to the left and up. (Fig. 44) When not in use,
the handle may be stored in the handle holder on the
right side of the rear shroud. (Fig. 47)

ST261

Stardance

operable doors

1/31/01

Clockwise

to Open

Counterclockwise

to Close

ST621

Fig. 44 To open the front doors, turn handle clockwise.

ST624

handle holder

2/6/01

Handle

Holder

ST624

Fig. 45 When not in use, store handle in the handle holder.

Your First Fire

Read these instructions carefully and familiarize your-
self with the burner controls. Locate the pilot assembly,
Figure 46. Follow the lighting instructions on Page 24
exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being heated.
Odors should dissipate within an hour or so, however,
you can open a window to provide fresh air to alleviate
the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in Figure
54. If flame patterns are incorrect, turn the heater off.
Contact your dealer or a qualified gas technician for as-
sistance. Do not operate the heater until the pilot flame
is correct.
Follow regular maintenance procedures as described
on Page 33.

ST477

Stardance

pilot location

10/4/00

ST476

Fig. 46 Pilot assembly location.

Flame & Temperature Adjustment

For stoves equipped with HI/LO valves, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control valve.
(Fig. 47)

LO

HI

Turn

counterclockwise

to decrease

flame height

Turn clockwise

to increase

flame height

HV102
Honeywell hi/lo knob
4/5/99 djt

Fig. 47 Flame adjustment knob for Honeywell valve.

Flame Characteristics

It is important to periodically perform a visual check
of the pilot and the burner flames. Compare them to
Figure 48. If any of the flames appear abnormal, call a
service person.

CO105c

Pilot flame

4/10/00 djt

LG142

Stardance

Install logs 2

12/11/00 djt

Red Glow

LG143

CO105c

Fig. 48 Correct pilot and burner flame patterns.

Advertising