22 - Chapter 2. Programming Interface

DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I

Command/Response Mode

2.2.4.2. Command/Response Mode

The Command/Response mode provides the following functionality:

•

A synchronous transfer mode for sending and returning responses from all Modbus and Application
Ethernet TCP/IP interfaces to serial and Ethernet TCP/IP devices.

•

Only one command message is transmitted at a time. Command messages are queued if a command
message is active.

•

Responses are routed only to the message sender.

•

Responses are timed out and old responses, (ones not requested within a certain time frame), destined for
the Modbus interface are discarded.

•

The expected response count is configurable. While this is typically one, some devices may return multiple
responses per message.

The Command/Response transfer mode is typically required in installations that require multiple controllers
sending raw/ASCII messages with expected responses, and it is desired that each controller only receive its
own responses.