Message structure execute_pccc: response message, Supported pccc command types – Comtrol IO-Link Master EIP-4 User Manual
Page 57

IO-Link Master EtherNet/IP Reference Manual: 2000589 Rev. A
Chapter 3. EtherNet/IP CIP Object Definitions - 57
Message Structure Execute_PCCC: Response Message
3.11.4. Message Structure Execute_PCCC: Response Message
This table displays the message structure for the Execute_PCCC Response Message for the PCCC Object.
3.11.5. Supported PCCC Command Types
The following table displays the Supported PCCC Command Types for the PCCC Object.
Name
Data Type
Description
Length
USINT
Length of requestor ID
Vendor
UINT
Vendor number of requestor
Serial Number
UDINT
ASA Serial number of requestor
CMD
USINT
Command byte
STS
USINT
Status Byte
TNSW
UINT
Transport word. Same value as request.
EXT_STS
USINT
Extended status. (If error)
PCCC_params
Array of USINT
CMD/FMC specific result data
CMD
FNC
Description
0F hex
A2 hex
SLC 500 protected typed read with 3 address fields
0F hex
AA hex
SLC 500 protected typed write with 3 address fields