AUTO MODE

When the Auto setting is selected, at startup the unit will run in
cooling, fan only, or heating based on the room temperature at

shown below.

64.4

68

73.4

77

Fan

Cooling

Heating

At Startup

Room Temp

er

ature

°F

A09357

Fig. 25 – AUTO Mode

After startup and if the unit is running in cooling, the compressor
will be de--energized when the room temperature is 73.4_F (23_C).

If the unit was running in heating, the compressor will be

de--energized when the room temperature is 73.4_F (23_C).
There is a 6 minute time delay before modes are switched.

SLEEP MODE

Additional energy savings can be realized by selecting the Sleep
mode. When the sleep setting is selected, the temperature set point

is adjusted automatically as shown below:

Cooling

Heating

1 HR

2 HR

T

S

T

S

+3.6°F

T

S

+1.8°F

T

S

-1.8°F

T

S

-3.6°F

A09258

Fig. 26 – SLEEP Mode