Amplifier – D.A.S. Audio Aero 20A User Manual

Page 10

Advertising
background image

AMPLIFIER

Description

1) INPUT :

XLR-type input signal connector. This is balanced connector just like the LOOP THRU connector with the

following pin assignments:

1 =GND (ground).

2 =(+) Non inverted input.

3 =(-) Inverted input.

2) LOOP THRU :

XLR-type output connector for connecting several units together and sending them all the same signal.

3) IN :

TM

Neutrik etherCon input connector for

DASnet .

4) OUT :

TM

Neutrik etherCon output connector for

DASnet , for connect more cabinets.

5) ON/PROTECT:

Two color LED which indicates that the unit is ON if shines green and protection if shines orange.

6) IDENTIFY/COMMS LED:

Green LED which blinks slowly when IDENTIFY is pushed (to indentify the unit) or, blink faster if there is

TM

communication with

DASnet .

7) SIGNAL/LIMIT :

Two color LED which indicates signal presence if shines green and limiter if shines red.

8) IDENTIFY KNOB :

It is used to indentify a unit in the software.

9) “THROW” SELECTOR:

A button that allows selecting the throw preset in the rear panel.

10) “THROW” LED:

The LED that shines indicates the selected preset.

11) “NUMBER OF UNITS” SELECTOR:

A button that switches between all the different pre configured array compensations (depending on the
number of cabinets)
12) “NUMBER OF UNITS” LED:

The LED shining indicates the selected preset.
13) QR :

QR symbol which allows the access, by internet, to the user´s manual.

14) ID DASNET :

TM

Tag with the ID number of the unit for

DASnet (more information in SYSTEM RECONFIGURATION).

15) AC INPUT :

Neutrik PowerCon TRUE1 mains connector. Only use this equipment with an appropiate mains

cord.
16) AC OUTPUT :

Neutrik PowerCon TRUE1 mains connector. Only use this equipment with an appropiate mains

cord.
17) RADIATOR :

Be careful when in contact with radiator because it can be hot, although it never will reach a dangerous

temperature.

10

Manual del Usuario

/ aero 2

0A

/ User’s Manual

NUMBER OF UNITS

UNIT NAME

STAGE / VENUE

THROW

115/230 V~ 50/60Hz 620W

AC INPUT

MAX. 5@230V / 2@115V UNITS AERO 20A

AC OUTPUT

ID DASNET

D.A.S. AUDIO S.A. (Valencia) MADE IN SPAIN

SIGNAL INPUT

IDENTIFY/COMMS

THROW

LOOP THRU

LONG

MID

SHORT

ON/PROTECT

SIGNAL/

LIMIT

NUMBER OF UNITS

16

8

4

2

12

6

3

1

20

CAUTION

DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

N1918

IN

OUT

14

17

15

16

7

5

1

6

8

2

3

4

9

10

13

11

12

Advertising