D.A.S. Audio SM Series User Manual

Page 16

Advertising
background image

EN

6

PROBLEM

CAUSE

SOLUTION

1- Turn down the mixer's output.

No sound from the unit.
The SIGNAL presence LED

indicator(s) do(es) not light up.

1- The signal source is sending
no signal.

2- Defective cable.

1- Check that the mixer or sound
source is sending signal to the UNIT.

2- Check that the cable from the
sound source to the UNIT is
connected correctly. Replace the
cable if defective.

Full power cannot be obtained.
The LIMIT

LED indicator(s) never

light(s) up.

1- The signal source does not have
a hot enough output.

1-

If using a mixer, use the balanced

output if available. Use a professional
mixer with a hotter output.

Sound is distorted.
The LIMIT

LED indicator(s) is/are not

on, or only light up occasionally.

1- The mixer or signal source

is distorting.

1- Turn mixer channel gains down.

Check that none of your signal

sources are distorting.

Sound is distorted and very loud.
One or more LIMIT

LED indicators

light up.

1-

The system is overloaded and

has reached maximum power.

Hum or buzz when a mixer
is connected to the unit.

1- The console probably has
un-balanced outputs. You may
be using an incorrect un-balanced
to balanced cable.

2- The mixer and the powered
speaker are not plugged into
the same mains outlet.

3- The audio signal cable is too
long or too close to an AC cable.

1- Read the appendix of this manual
to make a correct un-balanced to
balanced cable.

2- Connect the mixer and the unit
to the same mains outlet.

3- Use a cable that is as short as
possible and/or move the audio
signal cable away from mains cables.

Hum or buzz when using lighting
controls in the same building.

1- The audio signal cable is too
long or too close to the lighting cable.

2- On a sound system with three-

phase AC, the lighting equipment
and the UNIT are connected to
the same phase.

1-

Move the audio signal cable away

from lighting cables. Try to find out
at what point the noise is leaking
into the system.

2- Connect the sound system to
a different phase than the lights.
You may need the help of an electrician

The power on LED indicator(s) do(es)
not light up when the power connector
is rotated and locked at the
ON (LOCK) position.

1

Bad or loose AC connection to

the UNIT or the mains outlet.

2

Faulty AC cable.

3

Blown Fuse.

1-

Check you connections.

2- Check the cables, connectors
and AC power with a suitable

mains tester.

3- Replace fuse on fuse holder with
one of the same type. If it blows again,

take the unit to a service centre.

Troubleshooting

Manual del Usuario

/ stage monitors / User’s Manual

Advertising