TYPE PARAM1
PARAM2
PARAM3
PARAM4
DESCRIPCIÓN
SET
POWER
ON / STANDBY
Sets the current amplifier POWER status
LOAD_PRESET
<Preset Number>
Recalls and activates a PRESET
SAVE_PRESET
<Preset Number>
Saves the current PRESET
OUTPUT_MODE
<OutputMode>
Sets the current amplifier OUTPUT MODE
ZONE_LABEL
<Zone Label>
<Zone>
Sets the current LABEL (name) for the specified ZONE
MUTE
ON/OFF
<Zone>
Sets the current MUTE status for the specified ZONE
MASTER_VOL
<Volume Level>
<Zone>
Sets the current MASTER VOLUME for the specified ZONE
INPUT
<Input Name>
ON/OFF
<Zone>
Sets the status (ON/OFF) for the specified INPUT at the specified ZONE
VOL
<Input Name>
<Volume Level>
<Zone>
Sets the current VOLUME for the specified INPUT at the specified ZONE
BASS
<Input Name>
<Tone Level>
<Zone>
Sets the current BASS LEVEL for the specified INPUT at the specified ZONE
TREBLE
<Input Name>
<Tone Level>
<Zone>
Sets the current TREBLE LEVEL for the specified INPUT at the specified ZONE
GATE
<Micro Name>
ON/OFF
Sets the current NOISE GATE status (ON or OFF) for the specified MIC INPUT
GATE_THRESHOLD
<Micro Name>
<Threshold Level>
Sets the current NOISE GATE THRESHOLD LEVEL for the specified MIC INPUT
TALKOVER_ASSIGN
<Micro Name>
<Assign Value>
Sets the current TALKOVER ASSIGN for the specified MIC INPUT
TALKOVER_PRIORITY
<Micro Name>
<Priority number>
Sets the current TALKOVER PRIORITY for the specified MIC INPUT
TALKOVER_THRESHOLD <Micro Name>
<Threshold Level>
Sets the current TALKOVER THRESHOLD LEVEL for the specified MIC INPUT
TALKOVER_ATTACK
<Micro Name>
<Attack Time Value>
Sets the current TALKOVER ATTACK TIME for the specified MIC INPUT
TALKOVER_RELEASE
<Micro Name>
<Release Time Value>
Sets the current TALKOVER RELEASE TIME for the specified MIC INPUT
TALKOVER_DEPTH
<Micro Name>
<Depth Level>
Sets the current TALKOVER DEPTH (attenuation) for the specified MIC INPUT
MASTER_VOL_INC
<Increment Value>
<Zone>
Increments the current MASTER VOLUME for the specified ZONE
MASTER_VOL_DEC
<Increment Value>
<Zone>
Decrements the current MASTER VOLUME for the specified ZONE
REMOTE_SELECTOR
<Rem Select Value>
<Zone>
Sets de current REMOTE SELECTOR function for the specified ZONE
IR_REMOTE
ON/OFF
Sets the current IR REMOTE status (ON or OFF)
DISPLAY_MODE
<Display Mode>
Sets the current DISPLAY MODE
LCD_CONTRAST
<Contrast Level>
Sets the current DISPLAY CONTRAST level
AUTO_STANDBY
ON/OFF
Sets the current AUTO STANDBY function status (ON or OFF)
AUTOLOAD_PRESET1
ON/OFF
Sets the current AUTOLOAD_PRESET1 at Startup function
PANEL_LOCKED
ON/OFF
Sets the current PANEL_LOCKED (front panel controls) status