Ecler CA‐NET User Manual
Page 25
CA‐NET Protocol
page 25 / 33
XSELECT
<Input=I1:I5>
<Zone=ZA:ZD>
Gets the current CROSSPOINT SELECT status (ON (input active) or OFF
(input muted)) for the specified INPUT at the specified output zone
XLEVEL
<Input=I1:I5>
<Zone=ZA:ZD>
Gets the current CROSSPOINT LEVEL (mix level) for the specified INPUT
at the specified output zone
ZONE_LABEL
<Zone=ZA:ZD>
Gets the current LABEL (name) for the specified output zone
ZONE_STEREO
<Zone=ZA:ZD>
Gets the current STEREO link status (ON or OFF) the specified output
zone
ZONE_MUTE
<Zone=ZA:ZD>
Gets the current MUTE status (ON or OFF) for the specified output
zone
ZONE_VOL
<Zone=ZA:ZD>
Gets the current VOLUME for the specified output zone
GEQ_ACTIVE
<Zone=ZA:ZD>
Gets the current GRAPHICAL EQUALIZER status (ON or OFF) for the
specified output zone
GEQ_GAIN
<Zone=ZA:ZD>
<Band=B1:B10>
Gets the current GAIN (dBx10) of one BAND (B1 to B10) of the
GRAPHICAL EQUALIZER for the specified output zone
XOVER_ACTIVE
<Zone=ZA:ZD>
Gets the current CROSSOVER FILTER status (ON or OFF) for the
specified output zone
XOVER_TYPE
<Zone=ZA:ZD>
Gets the current CROSSOVER FILTER TYPE (LP or HP) for the specified
output zone
XOVER_FREQUENCY
<Zone=ZA:ZD>
Gets the current CROSSOVER FILTER FREQUENCY (Hz) for the specified
output zone