Junction Box Type KA – Technical Manual, Rev. 1.00 August 2007

Page 4 of 4

After all conductors have been connected, the cable glands must be tightened. Please verify that all cable
glands are tight and the cable is fully stress relieved.

O

UTPUT

C

ABLE

C

ONNECTION

The signal cable (connection between junction box and the following electronics) should be a 6 – wire
shielded cable and has to be kept as short as possible. Depending on type and manufacturer signal cables
may have different colours. Therefore make your own choice.

Cable colour, example

Beschreibung / Lötpunktbezeichnung

Terminal no., example

outer cable screen

= Shield

Second ground screw

yellow

= Sense +

1

green

= Excitation + (Input +)

2

white

= Signal + (Output +)

3

pink

= Signal – (Output –)

4

brown

= Excitation – (Input –)

5

grey

= Sense –

6


Figure 2: Wiring


Finally check the cover sealing and install the cover of the box.