Current chart – Great Planes Triton2 EQ Charger - GPMM3156 User Manual
Page 20
20
*Break-In Charge
CURRENT CHART
NiCd and NiMH CHARGE AND DISCHARGE CURRENT CHART
CHARGE CURRENT TIPS: This table shows recommended charge current settings for NiCd and NiMH batteries. Find the battery’s
rated capacity (mAh) in the left column. Determine how quickly you need to charge the battery, and find the corresponding current in
the columns to the right. * Follow the “Break-In Charge” column for batteries which are new, which have been in long-term storage, or
if a battery has accidently been discharged COMPLETELY (if a Tx or Rx power switch has been left on, for example). See the Setup
Menu for setting the number of minutes in the “Safety Timer” screen. The minutes shown for here are NOT RECOMMENDED for 2 hour,
1 hour, or quick charge currents.
DISCHARGE CURRENT TIPS: More accurate mAh measurements can be achieved when using a C/5 discharge current (battery capacity
divided by 5). Find the battery’s rated capacity (mAh) in the left column. Then move across to the far right to the C/5 Discharge Current
column to determine the proper discharge current setting to use.
Battery’s Rated
Capacity (mAh)
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
Current
0.1A
0.1A
0.1A
0.1A
0.1A
0.1A
0.1A
0.1A
0.1A
0.1A
0.2A
0.2A
0.2A
0.2A
0.2A
0.2A
0.2A
0.2A
0.2A
0.2A
0.3A
0.3A
0.3A
0.3A
0.3A
0.3A
0.3A
0.3A
0.3A
0.3A
0.4A
0.4A
0.4A
0.4A
0.4A
0.4A
0.4A
0.4A
0.4A
0.4A
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
Safety Timer Setting
84 minutes
168 minutes
252 minutes
336 minutes
450 minutes
540 minutes
630 minutes
720 minutes
864 minutes
960 minutes
495 minutes
540 minutes
585 minutes
630 minutes
675 minutes
720 minutes
816 minutes
864 minutes
912 minutes
960 minutes
630 minutes
660 minutes
690 minutes
720 minutes
750 minutes
832 minutes
864 minutes
896 minutes
928 minutes
960 minutes
697 minutes
720 minutes
742 minutes
816 minutes
840 minutes
864 minutes
888 minutes
912 minutes
936 minutes
960 minutes
738 minutes
756 minutes
825 minutes
844 minutes
864 minutes
883 minutes
902 minutes
921 minutes
941 minutes
960 minutes
2 Hour
Current
0.1A
0.1A
0.2A
0.2A
0.3A
0.3A
0.4A
0.4A
0.5A
0.5A
0.6A
0.6A
0.7A
0.7A
0.8A
0.8A
0.9A
0.9A
1.0A
1.0A
1.1A
1.1A
1.2A
1.2A
1.3A
1.3A
1.4A
1.4A
1.5A
1.5A
1.6A
1.6A
1.7A
1.7A
1.8A
1.8A
1.9A
1.9A
2.0A
2.0A
2.1A
2.1A
2.2A
2.2A
2.3A
2.3A
2.4A
2.4A
2.5A
2.5A
1 Hour
Current
0.1A
0.2A
0.3A
0.4A
0.5A
0.6A
0.7A
0.8A
0.9A
1.0A
1.1A
1.2A
1.3A
1.4A
1.5A
1.6A
1.7A
1.8A
1.9A
2.0A
2.1A
2.2A
2.3A
2.4A
2.5A
2.6A
2.7A
2.8A
2.9A
3.0A
3.1A
3.2A
3.3A
3.4A
3.5A
3.6A
3.7A
3.8A
3.9A
4.0A
4.1A
4.2A
4.3A
4.4A
4.5A
4.6A
4.7A
4.8A
4.9A
5.0A
Quick Charge
Current
0.2A
0.4A
0.6A
0.8A
1.0A
1.2A
1.4A
1.6A
1.8A
2.0A
2.2A
2.4A
2.6A
2.8A
3.0A
3.2A
3.4A
3.6A
3.8A
4.0A
4.2A
4.4A
4.6A
4.8A
5.0A
5.2A
5.4A
5.6A
5.8A
6.0A
6.2A
6.4A
6.6A
6.8A
7.0A
7.0A
7.0A
7.0A
7.0A
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
C/5 Discharge
Current
0.1A
0.1A
0.1A
0.1A
0.1A
0.1A
0.1A
0.2A
0.2A
0.2A
0.2A
0.2A
0.3A
0.3A
0.3A
0.3A
0.3A
0.4A
0.4A
0.4A
0.4A
0.4A
0.5A
0.5A
0.5A
0.5A
0.5A
0.6A
0.6A
0.6A
0.6A
0.6A
0.7A
0.7A
0.7A
0.7A
0.7A
0.8A
0.8A
0.8A
0.8A
0.8A
0.9A
0.9A
0.9A
0.9A
0.9A
0.9A
1.0A
1.0A