9 Appendix Ⅲ The relationship between the 24V AC cable

diameter and the transmission distance

It is the recommended transmission distance when the cable diameter is fixed and the 24V AC

power consumption is below 10%. For the AC device, the max permission voltage power

consumption is 10%. For example, when a device of rated power 80VA installed from the

transformer 35 inches (10m), then the min cable diameter is 0.8000mm.

Feet (m) mm

0.8000

1.000

1.250

2.000

10

283 (86)

451 (137)

716 (218)

1811 (551)

20

141 (42)

225 (68)

358 (109)

905 (275)

30

94 (28)

150 (45)

238 (72)

603 (183)

40

70 (21)

112 (34)

179 (54)

452 (137)

50

56 (17)

90 (27)

143 (43)

362 (110)

60

47 (14)

75 (22)

119 (36)

301 (91)

70

40 (12)

64 (19)

102 (31)

258 (78)

80

35 (10)

56 (17)

89 (27)

226 (68)

90

31 (9)

50 (15)

79 (24)

201 (61)

100

28 (8)

45 (13)

71 (21)

181 (55)

110

25 (7)

41 (12)

65 (19)

164 (49)

120

23 (7)

37 (11)

59 (17)

150 (45)

130

21 (6)

34 (10)

55 (16)

139 (42)

140

20 (6)

32 (9)

51 (15)

129 (39)

150

18 (5)

30 (9)

47 (14)

120 (36)

160

17 (5)

28 (8)

44 (13)

113 (34)

170

16 (4)

26 (7)

42 (12)

106 (32)

180

15 (4)

25 (7)

39 (11)

100 (30)

190

14 (4)

23 (7)

37 (11)

95 (28)

200 14

(4)

22 (6)

35 (10)

90 (27)

va