Intellijel Quadra + Expander User Manual

Intellijel Audio

Advertising
background image

Intellijel  

Quadra  Manual  

Version  1  

Page  |  1  
 

 

The  Intellijel  Quadra  and  Expander  module  comprises  four  parallel  function  generators  (more  commonly  referred  to  as  
“Envelope  Generators”.  The  Quadra  function  generators  have  three  modes,  AD  (Attack  Decay),  ASR  (Attack  Sustain  
Release)  and  Cycle  (perpetually  repeating  AR  envelope  or  unipolar  LFO).  Each  function  can  be  configured  to  have  a  linear  
or  exponential  curve  and  they  feature  a  wide  time  base  control  from  0.5ms  to  over  30  seconds.  The  Expander  enhances  
the  core  functionality  by  allowing  attenuated  voltage  control  over  Attack  and  Decay  for  each  function  generator  as  well  
as  a  Quadrature  mode  and  a  analog  OR  mixer  for  each  function  generator  pair  (1-­‐2,  3-­‐4).    

This  manual  will  cover  both  the  Quadra  and  its  optional  Expander  module.  

Quadra  Front  Panel  

1-­‐  ATTACK  –  These  knobs  control  the  time  of  the  
Attack  portion  of  the  function  (rising  from  0  to  the  
maximum  level).  Slower  times  will  create  a  fade  in  
effect  while  faster  times  are  used  for  snappy  
percussive  sounds.    
 
2-­‐  DECAY-­‐  These  knobs  control  the  fall  to  zero  time.  
If  in  ASR  mode  this  will  act  as  the  Release  time.  In  
Cycle  mode  the  total  time  of  Attack  and  Decay  set  
the  frequency  of  the  LFO.  
 
3-­‐  Exponential/Linear  switch.  This  will  change  the  
shape  of  the  Attack  and  Decay  sections.  This  setting  
will  alter  the  time  base  of  the  function  generator.  
Depending  on  what  you  are  patching  the  Quadra  into  
this  setting  may  need  to  be  changed.  For  example  if  
patching  into  an  exponential  VCA  you  should  use  
Linear  mode.  The  fastest  envelope  times  are  
achieved  when  in  linear  mode.  
 
4-­‐  Mode  switch.  Selects  AD,  ASR  or  Cycle  mode.  AD  is  
an  envelope  that  ignores  the  incoming  gate  time  and  
is  simply  triggered.  This  is  often  used  with  
sequencers.  ASR  is  similar  to  an  ADSR  in  that  it  
continues  to  sustain  while  the  input  gate  is  high  and  
Cycle  mode  is  like  a  LFO.  
 
5-­‐  LED  –  shows  the  state  of  the  function  generator  
amplitude.  
 
6-­‐  TRIG  Inputs  -­‐  Patch  trigger  or  gate  signals  here  to  
control  the  function  generators.  
 
7-­‐  ENV  Outputs  –  The  function  generator  is  output  
here  as  a  uniplolar  0-­‐8v  control  signal.  

 

Advertising