Troubleshooting – Interlogix MCR200-1T-1TW User Manual

Page 20

Advertising
background image

IFS MCR200-1T-1TW User Guide 17

Troubleshooting

SYMPTOM: VDSL LNK LED does not light after wire is connected to the
VDSL port.

CHECKPOINT:

1.

Verify the length of the wire connected between two MCR200-1T-1TW is not

more than 2.0km. Please also try to adjust the DIP switch of MCR200-1T-

1TW to other SNR mode.

2.

Please note you must use one MCR200-1T-1TW with CO mode and the other

MCR200-1T-1TW with CPE mode, connect to each other to make it work.

SYMPTOM: TP LED does not light after cable is connected to the port.

CHECKPOINT:

1.

Verify you are using the Cat.5, 5e or 6 cables with RJ-45 connector to

connect to the port.

2.

If your device (like LAN card) supports to Auto-Negotiation, please try to

modify at a fixed speed of your device by manually.

3.

Check the converter and the connected device’s power are ON or OFF.

4.

Check the port’s cable is firmly seated in its connectors in the switch and in

the associated device.

5.

Check the connecting cable is good.

Check the power adapters are functional, including the connecting device.