Put Sensor in Test Mode

1. Connect 9-volt battery to sensor for pre-testing.

2. Use double-stick tape provided to temporarily mount sensor

in desired location.

3. Use Sentrol 5709C Hand-Held Tester to put sensor into test

mode. Set tester to “tempered glass” and hold on top of

sensor. Activate tester — this will trip sensor into test mode

for one minute. In test mode, LED will blink continuously.

To extend test time, activate tester at least once a minute.

Test the Sensor (sensor must be in test mode, blinking)

1. The 5709C tester has settings for different types of glass.

Use “tempered” setting if unsure of glass type.

2. Hold tester near surface of glass to be protected and aim at

sensor. Press test button.

If drapes or blinds are present, hold the tester behind the

closed drapes or blinds.

3. If LED stays on for 4 seconds, glass is within detection range

of sensor.

4. If LED does not stay on, reposition the sensor and retest.

(Verify adequate battery strength in tester.)

ShatterPro sensors are omni-directional, providing 360° coverage.

Coverage is measured from the sensor to the point on the glass

farthest from the sensor. The sensor can be mounted as close as

3.3' (1 m) from the glass.

1. Mounted on opposite wall or adjoining walls, range is 25 ft.

(7.5m) for plate, tempered, laminated and wired glass.

2. Mounted on the ceiling, maximum range is 25 ft. (7.5m) for

plate, tempered, laminated and wired glass.

3. For armor-coated glass, mount sensor no more than 12 ft.

(3.65m) from glass.

Recommended Glass Size:

Minimum 1' x 2' (0.3 m x 0.6 m) or larger

Glass thickness:

Plate: 3/32" to 1/4" (2.4 mm to 6.4 mm)

Tempered: 1/8" to 1/4" (3.2 mm to 6.4 mm)

Wired: 1/4" (6.4 mm)

Laminated: 1/8" to 1/4" (3.2 mm to 6.4 mm)

For Best Detection, Avoid Installing In:

•

Rooms with lined, insulating, or sound deadening drapes.

•

Rooms with closed wooden window shutters inside.

How Test Mode Works:

Test Mode is activated by the hand-held tester when the tester is

held directly over the microphone and set off. The sensor’s LED

will blink continuously for 1 minute. During this time, the

installer can test the unit using the instructions above. When the

system is armed and the ShatterPro trips to an alarm condition,

the LED will latch solid for 4 seconds and then revert back to a

1- minute test mode. At the end of 1 minute, the LED will

extinguish.

25' (7.5 m)

25' (7.5 m)

RANGE OF COVERAGE

TESTING THE SENSOR

• Single

• Continuous

Plate •

Tempered •

Laminated •

Battery LED

Battery is OK if LED

stays on during test

5709C

Shatter Series T

ester

Use for testing:

ShatterPro

Shatterbox

Shatterbox II

ShatterSwitch

SENTROL

Hold tester so that the speaker is
within 1 inch of sensor microphone

In test mode the sensor LED will light
solid for about 4 seconds,
then blink for about a minute