Electrical

Voltage ...................................................................... 9 to 16 VDC

Current ............................................... 12 mA typical, 25 mA max.

Relay output ............Normally closed, open 4 seconds upon alarm

On resistance ................................................ 10 Ohm – 5 +10

Off resistance ....................................................... > 1 MOhms

Maximum loop rating (relay or tamper loop) .........................

...................................................................... 16 VDC, 50 mA

Wiring terminals .........................................................22-18 AWG

Environmental

Lightning suppression .......................... 400 watts for 1 msec pulse

RF Immunity .............................. 20V/m min from 1MHz to 1GHz

Microphone............................................ Omni-directional electret

Operating Temperature ............. 0° F to 120° F (-18° C to +50° C)

Humidity ............................................10% to 90% noncondensing

NOTE: This equipment has been tested and found to comply

with the limits for a Class B digital device, pursuant to Part 15 of

the FCC Rules. These limits are designed to provide reasonable

protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency

energy and, if not installed and used in accordance with the

instructions, may cause harmful interference to radio communica-

tions. There is no guarantee that interference will not occur in a

particular installation. If this equipment does cause harmful

interference to radio or television reception, which can be

determined by turning the equipment on and off, the user is

encouraged to try to correct the interference by one or more of the

following measures:

• Re-orient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different

from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for

help.

Under FCC Rules, Part 15 for Class B digital devices, operation is

subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, includ-

ing interference that may cause undesired operation.