Installing the sureshot – Interlogix 6250 Series User Manual

Page 2

Advertising
background image

Avoid False Alarm Sources

Sunlight or
reflected sunlight

Pets

Intermittent
heat sources

Hot or cold air
directed onto sensor

6. Choose which masking plate you need, if any. Insert

behind lens on front cover by pressing over four mounting
pins. Once front cover is installed the masking plate will be
held tight against the lens.

Note: Masking plates have two notches to prevent

incorrect installation. One notch matches a rib
in the front cover. The second notch matches a
dimple in the lens.

INSTALLING THE SURESHOT

1. Remove front cover by gently prying apart at bottom. Front

cover hinges at top.

2. Remove circuit board assembly by holding pyro shield and

pulling out of back cover.

3. Mount back cover to ceiling, wall or corner. For wall

mounting, make sure "up" arrow is pointing up. Use
appropriate mounting knockouts.

Mounting

UP

MADE IN U.S.A.

1-800-547-2556

Knockouts for

Wall or Ceiling

Mounting

Knockouts for

Corner Mounting

Wiring Knockouts

Wiring Knockouts

Knockouts for

Wall or Ceiling

Mounting

Knockouts for
Wall or Ceiling
Mounting

Knockouts for
Corner Mounting

Knockouts for
Wall or Ceiling
Mounting

4. Snap circuit board assembly back into back cover by

aligning lower edge of board with circuit board guides and
pressing into place.

5. Connect wires per "wiring" diagrams on following page. A

wiring diagram is also included on the inside of the front
cover. You can strain relieve your wire cable by wrapping
it around the strain relief posts in the lower corners of the
back cover.

Note: To correctly mount the Pet Alley Mask, the lens

must be removed from the front cover and
rotated 180

o

.

7. Replace front cover.

Note:

When mounting on the ceiling, align the unit to
maximize the oblong detection pattern for the room.

Capture zone

at 8' (2.4m) mounting height

8. After walk testing, the LED cover can be slid up to cover

the LED.

Note: Unit should be walktested monthly to ensure continual

20' (6.12m)

WIDE

ANGLE

Align notch
with dimple

Inside of

Front Cover

Align notch
with rib

PET

ALLEY

ROTATE LENS

180

o

Rotate
Lens 180°

Inside of

Front Cover

Align notch
with dimple

For false-alarm-free operation, a PIR should not “see"
sources of heat or cold.

15'

(4.59m)

Advertising