PART

LOOP

ELECTRICAL

LISTING

NUMBER

TYPE

CONFIGURATION

6255

Normally Closed

N.C.

UL

6257

Normally Closed or Open

SPDT (N.C. and N.O.)

UL

SURESHOT SPECIFICATIONS

6255

6257

ELECTRICAL

Voltage ................. 10 to 16 VDC ................ 7 to 16 VDC
Current ................. 14mA typical, ................ 8mA typical,

20mA max.

10mA max

Max. relay rating ... 16VDC, 50 mA .............. 16VDC, 50 mA
Alarm output ...... Fail safe contacts .......... Fail safe contacts

w/10 ohms in series

Form A, ........................ Form C,

Normally Closed (NC) ... Normally Closed and

Open (SPDT)

Alarm duration ..... 2 to 5 seconds ............. 2 to 5 seconds
Cover tamper ..... Normally Closed, ......... Normally Closed,
contacts

rating: 50 mA, 12VDC .. rating: 50 mA, 12VDC

ENVIRONMENTAL
Operating Temp. .... 0

°

F to 120

°

F ................ 0

°

F to 120

°

F

(-17

°

C to +50

°

C) .......... (-17

°

C to +50

°

C)

Humidity ................ 10% to 90% ................. 10% to 90%

noncondensing ............ noncondensing

RFI immunity ..... greater than 20V/m ...... greater than 10V/m

from 0 to 1000MHz ....... from 0 to 1000MHz

Static immunity ............ 20KV .......................... 2.5KV
Lightning immunity ..... 2.4KV, .......................... 2.5KV,

1.2 joules max energy .... 2 joules max energy

impulse,

impulse,

100

µ

sec duration ..... 1msec rise/50 msec

in field wiring

decay

1.20"

(3.05 cm)

Side View

Front View

2.25”

(5.72 cm)

3.75”

(9.52 cm)

P-3172
14377 Rev A

12345 SW Leveton Dr.

Tualatin, OR 97062

Tel.: 503.692.4052 Fax: 503.691.7566

U.S. & Canada: 800.547.2556
Technical Service: 800.648.7424
FaxBack: 800.483.2495

CORPORATE HEADQUARTERS

Sentrol reserves the right

to change specifications

without notice.

©1999 Sentrol

SENTROL

FEATURES
Pulse Count ......................... Bi-directional, 1 zone (2 pulses)

with Motion Verification

Capture Zone (at 70˚ F)

Wide Angle (90˚) ....................... 30' (9.14m) x 30' (9.14m)
Single Spot ...................................... 40' (12.19m) range
Vertical Barrier ................................... 40' (12.19m) range
Pet Alley (90˚) ...................................... 30' (9.14m) range
360

°

Ceiling ......... 15' x 20' (4.57m x 6.10m) at 8' (2.44m)

mounting height

........ 16' x 30' (4.88m x 9.14m) at 12' (3.65m)

mounting height

...... Ceiling mounting height up to 12'(3.65m)

Mounting ............................................ Wall, corner, or ceiling
LED indicator .......................................................... Walktest
Size ............................................................. 2.25"(5.72cm)W

3.75" (9.52cm)H
1.20" (3.05cm)D

Color ................................................................. White/White

3.75"

(9.52cm)

2.25"

(5.72cm)

Front View

1.20"

(3.05cm)

Advertising