En: installation sheet, Introduction, Installation guidelines – Interlogix EV1012 User Manual

Page 3: Installing the detector

Advertising
background image

P/N 146169999-10 • REV C • ISS 02APR12

3 / 36

8

1A

1B

9A

9B

2B-3B

7B-8B

5B

4

6

1A

1B

2B

3B

4

9B

8B

7B

6

9A

5B

(3) 5 curtains

6 m range

(4) 7 curtains

6 m range

(1)

(2)

(5) 5 curtains

12 m range

(6) 7 curtains

12 m range

(7) 9 curtains

12 m range

EN: Installation Sheet

Introduction

The EV1000 series includes models EV1012 and EV1012AM.
These detectors have a patented mirror, pyro, and signal
processing technology.

Note:

EV1012AM has not been evaluated by UL/cUL.

Installation guidelines

The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Figure 1):

•

Direct sunlight on the detector

•

Strong draughts onto the detector

•

Heat sources within the detector field of view

•

Large animals within the detector field of view

•

Obscuring the detector field of view with large objects,
such as furniture

•

Objects within 50 cm (20 in.) of the anti-masking (AM)
detector

•

Installing two detectors facing each other and less than
50 cm (20 in.) apart

Installing the detector

Figure 7 legend

Item Description

(1)

Standard connection (factory default)

(2)

Dual loop connection

CP Control

panel

WT Walk

test

AM Antimasking

D/N Day/night

Rtest Remote

test

To install the detector:

1. Lift off the custom insert and remove the screw

(see Figure 2, item 1).

2. Using a screwdriver, carefully prise open the detector (see

Figure 2, items 2 and 3).

3. Fix the base to the wall between 1.8 m and 3.0 m (5.9 and

9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 3). To install a pry-
off tamper, use position A or B.

Note:

Using the pry-off tamper has not been evaluated by

UL/cUL.

Advertising