15

BURNER INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount

of air to mix with the gas. This provides a clean

burning flame. Keep these holes clear of dust, dirt,

lint and pet hair. Clean these air inlet holes prior to

each heating season. Blocked air holes will create

soot. We recommend that you clean the unit every

three months during operation and have heater

inspected yearly by a qualified service person.
We also recommend that you keep the burner

tube and pilot assembly clean and free of dust

and dirt. To clean these parts we recommend us-

ing compressed air no greater than 30 PSI. Your

local computer store, hardware store or home

center may carry compressed air in a can. You

can use a vacuum cleaner in the blow position. If

using compressed air in a can, please follow the

directions on the can. If you don't follow directions

on the can, you could damage the pilot assembly.

Note:

Removing the rear panel and top grates of

your stove will make cleaning easier.
1. Shut off the unit, including the pilot. Allow

the unit to cool for at least thirty minutes.

2. Inspect burner, pilot and primary air inlet

holes on injector holder for dust and dirt (see

Figure 20).

3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large

particles of dust, dirt, lint or pet hair with a

soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

two inches from where the pilot flame comes out

of the pilot assembly (see Figure 21). With the unit

off, lightly blow air through the air inlet hole. You

may blow through a drinking straw if compressed

air is not available.

CLEANING AND

MAINTENANCE

Continued

Figure 20 - Injector Holder On Outlet

Burner Tube

Burner
Tube

Injector Holder
(May Be Brass or
Aluminum Depending
on Model)

Primary Air Inlet
Holes (Shape of
Holes May Vary
by Model)

Figure 21 - Pilot Inlet Air Hole

Burner
Tube

Pilot
Assembly

Pilot Air
Inlet Hole

Ports/Slots

LOGS

• If you remove logs for cleaning, refer to Install-

ing Log Set, page 12, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

Advertising
This manual is related to the following products: