match, replace indoor coil piston with piston shipped with outdoor
unit. The piston shipped with outdoor unit is correct for any
approved indoor coil combination.

Do not operate unit in the vicinity of toxic or flammable
material. Failure to follow this warning can result in personal
injury, fire, or death.

Remove indoor coil piston if unit is to be installed on system
with a TXV metering device.

Step 5—Make Piping Connections

Relieve pressure and recover all refrigerant before system
repair or final unit disposal to avoid personal injury or death.
Use all service ports and open all flow-control devices,
including solenoid valves.

Fig. 2—Unit Reference Drawing

UNIT

SIZE

A/B

C

D

E

F

G

In.

mm

In.

mm

In.

mm

In.

mm

In.

mm

In.

mm

024

22-1/2

571.5

3-11/16

93.6

18-1/8

460.4

14-3/8

365.1

5/8

15.88

33-15/16

862.0

036

30

762.0

6-1/2

165.1

23-1/2

596.9

20

508.0

3/4

19.05

39-15/16

1014.4

048

30

762.0

6-1/2

165.1

23-1/2

596.9

20

508.0

7/8

22.23

33-15/16

862.0

060

30

762.0

6-1/2

165.1

23-1/2

596.9

20

508.0

7/8

22.23

33-15/16

862.0

A97004

AIR DISCHARGE

3

/

8

DIA

LIQUID LINE CONN

FIELD CONTROL
SUPPLY CONN

7

/

8

DIA HOLE

AIR

DISCHARGE

AIR
DISCHARGE

AIR IN

AIR IN

1. ALLOW 30

CLEARANCE TO SERVICE END OF

UNIT, 48

ABOVE UNIT, 6

ON ONE SIDE, 12

ON REMAINING SIDE, AND 24

BETWEEN

UNITS FOR PROPER AIRFLOW.
2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS
55

°

F (UNLESS LOW AMBIENT CONTROL IS USED) MAX. 115

°

F.

3. MAXIMUM OUTDOOR OPERATING AMBIENT IN HEATING MODE IS 66

°

F.

4. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT
MODEL NUMBER.

NOTES:

FIELD POWER
SUPPLY CONN

7

/

8

DIA HOLE WITH

1

1

/

8

DIA KNOCKOUT

AND 1

3

/

8

DIA KNOCKOUT

A

D

AIR IN

E

B

AIR

IN

C

F

DIA SUCTION LINE CONN

G

Fig. 3—Accessory Heat Pump Feet

A97006

SERVICE
ACCESS

2

Advertising