Troubleshooting Chart (Continued)

Symptom

Possible Cause(s)

Corrective Action

4 . Tank leaks

5. Broken valves
6. Piston ring worn

1 . Excessive water in tank
2 . High humidity

1 . Defective pressure switch
2 . Defective safety valve

1. Excessive condensation in tank
2 . Loose connections at fittings, tubing,

e t c .

3 . Tank leaks

1 . Check valve stuck in an open position
2 . Unloader valve stuck in open position

4 . Check tank for leaks with soap and water solution. If

leak is detected, tank must be replaced with genuine
replacement part.

5 . Replace compressor valves as necessary.
6 . Replace piston and cylinder.

1 . Drain tank.
2 . Move to area of less humidity; use air line filter.

NOTE: Water condensation is not caused by
compressor malfunction.

1 . Replace switch.
2 . Replace safety valve with genuine replacement part.

1 . Drain more often.
2 . Check all connections with soap and water solution.

If a leak is detected, (1) tighten or (2) remove fitting
and apply pipe tape to threads and reassemble.

3 . Check tank for leaks with soap and water solution. If

leak is detected, tank must be replaced with genuine
replacement part.

Do not disassemble check valve
with air in tank; bleed tank

1 . Repair or replace check valve.
2 . Repair or replace unloader valve.

Do not disassemble check valve
with air in tank; bleed tank

Excessive moisture in
discharge air

Compressor runs
continuously and safety
valve opens as pressure
r i s e s

Excessive starting and
stopping (auto start)

Air leaking from
unloader valve on
pressure switch

w w w . c h p o w e r . c o m