Troubleshooting the Installation

202 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches, version 4.5

●

Mis-configuration

●

Use the show port CLI
command to show the port
parameters and check they are
compatible with the attached
device.

●

Faulty NIC

●

Replace the NIC

Connected device does not receive power from switch (C360-PWR
only)

Tip:

Tip:

Use the show powerinline CLI command to show
PoE status

●

Device connected is
not a PD (powered
device), such as a
computer
(PoE LED blinks)

●

Check that the cable to the PD is
inserted and connected correctly

●

PD not connected
properly (PoE LED
blinks)

●

PD not compatible
(PoE LED blinks)

●

Switch Inline power
capacity exceeded
(PoE LED blinks)

●

Increase the priority of the PD
port to High or Critical (see page)

●

Move the PD to a
higher-numbered port

●

Disconnect unnecessary PDs
from the switch.

●

Connect an additional Inline DC
power source to the switch

●

Overcurrent or
undercurrent detected.

●

Check that the PD is working
correctly.

Table 35: Troubleshooting 2 of 3

Problem/Cause

Suggested Solution

2 of 3