Connecting to a DC Power Source (C364T NEBS Only)

Issue 1 July 2006

51

Connecting to a DC Power Source (C364T NEBS Only)

The C364T NEBS is rated -36 to -60 VDC, 2A.

!

CAUTION:

CAUTION:

A UL-Listed and CSA-Certified branch circuit protective device of up to 20A must
be provided in the building DC mains wiring installation for branch circuit
protection.

!

CAUTION:

CAUTION:

Always connect the ground wire first and disconnect it last.

Figure 17: Avaya C360 DC Input Terminal Block

●

The terminals are marked with

, “+” and “-“.

●

The size of the two screws in the terminal block is M4.

●

The pitch between each screw is 9.5mm.

4. Remove the protective plastic cover over the DC inputs by unscrewing the two Phillips

screws.

!

WARNING:

WARNING:

The conductors to be used for connecting the DC power supply to the C360 must
be UL Recognized and CSA Certified and be a minimum of 16 AWG or have a
cross-sectional area of 1.0mm

2

.

!

ADVERTENCIA:

ADVERTENCIA:

Los conductores que se utilizarán para conectar la fuente de alimentación
externa con el C360 deben ser Reconocidos por UL, Certificados por CSA y ser
como mínimo de 16 AWG o tener un área de sección transversal de 1.0 mm

2

.

5. Connect the power cable to the terminals on the C360 and to the external DC power supply

in the following sequence:

1. Ground wire to grounding post

Figure notes:

1. Protective plastic cover

2. BUPS DC input terminals

3. Grounding post

1

2

3

Advertising