Switching waveforms – Cypress CY62167DV18 User Manual

Page 6

Advertising
background image

CY62167DV18 MoBL

®

Document #: 38-05326 Rev. *C

Page 6 of 11

Switching Waveforms

Read Cycle 1 (Address Transition Controlled)

[14, 15]

Read Cycle 2 (OE Controlled)

[15, 16]

PREVIOUS DATA VALID

DATA VALID

RC

t

AA

t

OHA

t

RC

ADDRESS

DATA OUT

50%

50%

DATA VALID

t

RC

t

ACE

t

DOE

t

LZOE

t

LZCE

t

PU

HIGH IMPEDANCE

t

HZOE

t

PD

t

HZBE

t

LZBE

t

HZCE

t

DBE

OE

CE

1

ADDRESS

CE

2

BHE/BLE

DATA OUT

V

CC

SUPPLY

CURRENT

HIGH

I

CC

I

SB

IMPEDANCE

Notes

14. The device is continuously selected. OE, CE

1

= V

IL

, BHE and/or BLE = V

IL

, and CE

2

= V

IH

.

15. WE is HIGH for read cycle.
16. Address valid before or similar to CE

1

, BHE, BLE transition LOW and CE

2

transition HIGH.

[+] Feedback

Advertising