2.5V TAP AC Test Conditions

Input pulse levels ............................................... V

SS

to 2.5V

Input rise and fall time .................................................... 1 ns

Input timing reference levels ........................................1.25V

Output reference levels ................................................1.25V

Test load termination supply voltage .............................1.25V

2.5V TAP AC Output Load Equivalent

TDO

1.25V

20pF

Z = 50

O

50

TAP DC Electrical Characteristics And Operating Conditions

(0°C < TA < +70°C; VDD = 2.5V ±0.125V unless otherwise noted)

[13]

Parameter

Description

Test Conditions

Min.

Max.

Unit

V

OH1

Output HIGH Voltage

I

OH

= –1.0 mA, V

DDQ

= 2.5V

2.0

V

V

OH2

Output HIGH Voltage

I

OH

= –100 µA,V

DDQ

= 2.5V

2.1

V

V

OL1

Output LOW Voltage

I

OL

= 8.0 mA, V

DDQ

= 2.5V

0.4

V

V

OL2

Output LOW Voltage

I

OL

= 100 µA

V

DDQ

= 2.5V

0.2

V

V

IH

Input HIGH Voltage

V

DDQ

= 2.5V

1.7

V

DD

+ 0.3

V

V

IL

Input LOW Voltage

V

DDQ

= 2.5V

–0.3

0.7

V

I

X

Input Load Current

GND < V

IN

< V

DDQ

–5

5

µA

Identification Register Definitions

Instruction Field

CY7C1354CV25

CY7C1356CV25

Description

Revision Number (31:29)

000

000

Reserved for version number.

Cypress Device ID (28:12)

01011001000100110

01011001000010110 Reserved for future use.

Cypress JEDEC ID (11:1)

00000110100

00000110100

Allows unique identification of SRAM vendor.

ID Register Presence (0)

1

1

Indicate the presence of an ID register.

Scan Register Sizes

Register Name

Bit Size (x36)

Bit Size (x18)

Instruction

3

3

Bypass

1

1

ID

32

32

Boundary Scan Order (119-ball BGA
package)

69

69

Boundary Scan Order (165-ball FBGA
package)

69

69

Identification Codes

Instruction

Code

Description

EXTEST

000

Captures the Input/Output ring contents. Places the boundary scan register between the TDI and
TDO. Forces all SRAM outputs to High-Z state.

IDCODE

001

Loads the ID register with the vendor ID code and places the register between TDI and TDO. This
operation does not affect SRAM operation.

SAMPLE Z

010

Captures the Input/Output contents. Places the boundary scan register between TDI and TDO.
Forces all SRAM output drivers to a High-Z state.

RESERVED

011

Do Not Use: This instruction is reserved for future use.

SAMPLE/PRELOAD

100

Captures the Input/Output ring contents. Places the boundary scan register between TDI and TDO.
Does not affect the SRAM operation.

RESERVED

101

Do Not Use: This instruction is reserved for future use.

RESERVED

110

Do Not Use: This instruction is reserved for future use.

BYPASS

111

Places the bypass register between TDI and TDO. This operation does not affect SRAM operation.

Note:

13. All voltages referenced to V

SS

(GND).

[+] Feedback