Inspecting burners, Cleaning and maintenance, Operating heater – Desa Tech CSPINT User Manual

Page 14

Advertising
background image

www.desatech.com

111487-01E

14

OPERATING HEATER

Continued

Note:

The correct pilot flame on natural gas units

will have a slight curve, but flame should be blue

and have no yellow or orange color.

Figure 18 - Correct Pilot Flame Pattern

(Propane/LP Shown)

Thermocouple

Pilot
Burner

Pilot Burner

Thermocouple

Figure 19 - Incorrect Pilot Flame Pattern

(Propane/LP Shown)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater
Turn control knob clockwise

to the

OFF position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise

to the

PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any

comfort level between HI and LO. The ther-

mostat will gradually modulate the heat output

and flame height from higher to lower settings

or pilot, in order to maintain the comfort level

you select. The ideal comfort setting will vary

by household depending upon the amount of

space to be heated, the output of the central

heating system, etc.
Note:

Selecting the HI setting with the control

knob will cause the burner to remain fully on,

without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions

, page 13.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 8 in Lighting

Instructions

, page 13.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat-

terns often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern.

Figure 19 shows an incorrect pilot flame pattern.

The incorrect pilot flame is not touching the

thermocouple. This will cause the thermocouple

to cool. When the thermocouple cools, the heater

will shut down.
If pilot flame pattern is incorrect, as shown in

Figure 19
• turn heater off (see To Turn Off Gas to

Appliance

)

• see Troubleshooting, page 16

CLEANING AND

MAINTENANCE

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep con-

trol areas, burner and circulating

air passageways of heater clean.

Inspect these areas of heater

before each use. Have heater

inspected yearly by a qualified

service person. Heater may need

more frequent cleaning due to

excessive lint from carpeting, pet

hair, bedding material, etc.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clear may result in

sooting and property damage.

MAIN BURNER

Periodically inspect all burner flame holes with

the heater running. All slotted burner flame holes

should be open with yellow flame present. All

round burner flame holes should be open with a

small blue flame present. Some burner flame holes

may become blocked by debris or rust, with no

flame present. If so, turn off heater and let cool.

Remove blockage. Blocked burner flame holes

will create soot.

Advertising