Installation – Desa Tech CSPINT User Manual

Page 8

Advertising
background image

www.desatech.com

111487-01E

8

INSTALLATION

NOTICE: This heater is intended

for use as supplemental heat.

Use this heater along with your

primary heating system. Do not

install this heater as your pri-

mary heat source. If you have a

central heating system, you may

run system’s circulating blower

while using heater. This will help

circulate the heat throughout the

house. In the event of a power

outage, you can use this heater

as your primary heat source.

WARNING: A qualified ser-

vice person must install heater.

Follow all local codes.

WARNING: Never install the

heater

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture,

clothing or other flammable

objects are less than 42 inches

from the front, top or sides of

the heater

• in high traffic areas

• in windy or drafty areas

CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing heater

in rooms without enough ventilation air may cause

mildew to form from too much moisture. See Air

for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for

your unit. If your stove heater gas type is different

from your house gas type, do not install heater.

Call dealer where you bought heater for proper

type heater.

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

CLEARANCES TO COMBUSTIBLES
(Vent-Free Operation Only)

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining side

and back walls.

Carefully follow the instructions below. This stove

is a freestanding unit designed to set directly on the

floor. DO NOT place stove directly on carpeting,

vinyl tile or any combustible material other than

wood. The stove must be set on a metal or wood

panel extending the full width and depth of the

stove for these floor coverings. Important: You

must maintain minimum wall and ceiling clear-

ances during installation. The minimum clearances

are shown in Figure 5, page 9. Measure from

outermost point of stove top.
Minimum Wall and Ceiling Clearances
(see Figure 5, page 9)
A. Clearances from outermost point of stove top

to any combustible side wall should not be

less than 12 inches.

B. Clearances from outermost point of stove top

to any combustible back wall should not be less

than 6 inches (includes corner installations).

C. Clearances from the stove top to the ceiling

should not be less than 48 inches.

Advertising
This manual is related to the following products: