The first five bytes are always the same for all data types;

[ 1]

F0h

- Sysex command

[ 2]

00h

- Company identity first byte

[ 3]

20h

- Company identity second byte

[ 4]

13h

- Company identity third byte

[ 5]

11h

- Product code

[ 6]

0dddnnnn

- where nnn = MIDI channel & ddd = data type
if ddd = 000 = set system parameters
if ddd = 001 = set output relays
if ddd = 010 = information request
if ddd = 011 = memory request
if ddd = 100 = switch `Thru` to `Thru`
if ddd = 101 = switch `Thru` to `Out`
if ddd = 110 = direct system control

Note that the unit must be set to channel nnnn for any ddd to have effect.

______________________________________________________________

ddd = 000 = set system parameters

[ 7]

0000nnnn

- where nnnn = the new MIDI channel

[ 8]

0000AB65

- where 5 & 6 = set out #5 & 6 to `AMP`
where A & B = set amp. #A & B to `MOM`

Note that all bits are active high.

[ 9]

F7h

- end of exclusive

______________________________________________________________

ddd = 001 = set output relays

[ 7]

00004321

- where 4321 = out #4, 3, 2, & 1

[ 8]

0000AB65

- where AB65= amp. # A & B, out #6 & 5

Note that all bits are active high.

[ 9]

F7h

- end of exclusive

______________________________________________________________

ddd = 010 = information request

[ 7]

000000bb

- where bb = memory area
valid = 00 = patch data 01-64

01 = patch data 65-128
02 = controller assignment & system set-up

[ 8]

F7h

- end of exclusive

Note that the GS-8 saves the area requested via the MIDI Thru socket. The Thru socket must be