11.0

Troubleshooting the IntelliProx

12.0

Ordering Information

NOTE: Due to the physical size difference between cards and tags, tags provide approximately 50% less read range
than cards.

Problem

Probable Cause

Corrective Action

When a valid card is presented and the
door is opened, the Reader BEEPs
continually.

The door switch is not connected
or is not being used.

Connect the door switch or install a
jumper across Pins 13 and 17.

The IntelliProx is not granting access
to any card.

JP1 is installed.

Turn power OFF and remove JP1.
NOTE: Your card database and PIN
are may be erased and may have to be
restored.

When using the IntelliProx for
optional back-up door control, a card
continues to have access after being
voided from the host system.

The card is still enrolled in the
IntelliProx database.

Delete the card from the IntelliProx.

IntelliProx LED not lit

RS–232 communication line
interrupted.

Verify communication line is
functioning properly.

Reader Range

Model

P/N

at 5 VDC

at 12 VDC

at 24 VDC

IntelliProx
Smart Module

SM–2000

IntelliProx + MicroStar
Door Frame Mullion Mount
Reader

IP–2003

up to 3 inches

(7.6 cm)

up to 4 inches

(10.2 cm)

IntelliProx + ShootingStar
Vandal Resistant Reader

IP–2004

up to 1 inch

(2.5 cm)

up to 1 inch

(2.5 cm)

IntelliProx + MiniStar
Wall Switch Mount Reader

IP–2005

up to 4 inches

(10.2 cm)

up to 6 inches

(15.2 cm)

IntelliProx + SuperStar
Medium Range Reader

IP–2007

up to 14 inches

(35.5 cm)

Advertising