1 connecting wires - removing terminal blocks, 2 lc-202p wiring connections, 1 floor control relay – Keri Systems LC-208 Proximity Elevator Control User Manual

Page 9: Proximity elevator control panel

Advertising
background image

Proximity Elevator Control Panel

1530 Old Oakland Road, Suite 100

01879-001 Rev. E

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 9 of 22

LC-202P/LC-208P

Quick Start Guide

5.1

Connecting Wires - Removing Terminal Blocks

Follow the instructions in Figure 4 when connecting wires to the controller or when removing
terminal blocks from the controller.

Figure 4: Connecting Wires and Removing Terminal Blocks

5.2

LC-202P Wiring Connections

The following connections are made to install the LS-202P Elevator Control panel (see Figure 3 on
page 8).

Floor Control Relay via TB-A

RS-485 Controller Network via TB-B (network out) and TB-C (network in)

Reader Daisy-Chain via TB-B (reader output) and TB-C (reader input)

Earth Ground and Power via TB-C

5.2.1

Floor Control Relay

The Floor Control Relay is connected to the floor controls at the elevator panel. If a controller has
an SB-200 Satellite Board attached to control two floors, connect the lower floor to the A-Floor
Control Relay and connect the higher floor to the B-Floor Control Relay. Make the floor control
relay connections per the information in Table 2 and Figure 5 on page 10.

Table 2: Floor Control Relay

Connection

LC-200P TB-3 Pin

SB-200 TB-7 Pin

Description

1

Normally-Open

2

Common

3

Normally-Closed

Advertising
This manual is related to the following products: