4.6. Cueing device adjustment:
Should you find that in the ‘up’ position the cartridge is too high or too low above the record
then the cueing device can be raised or lowered. This can be done simply by using Allen key
1.5 mm:
Insert key into the screw on the side of the arm rest.
Release the screw, raise or lower the device and retighten.
Rotation of the cueing device can affect the drift of cartridge while traveling vertically down.

The cueing device may lift slightly as the screw is retightened. Do not over-tighten as this may
cause the cueing device to stick in the ‘up’ position. Should this occur, slightly release the
screw?

5.0. Maintenance:

5.1. General:
The bearing does not need maintenance. Dust only with a soft brush, do not blow away dust.

If the tonearm is mounted on a wooden armboard the base may need to be retightened in the

board after a few weeks.

5.2. Checking bearings for play:
Holding the headshell, gently try to rotate tube of arm. There should be no movement or
audible clicking. If there is, consult your dealer.

Note: Ensure that Azimuth and height adjustment screws are fixed before
attempting the above.

5.3. Checking bearings friction:
Replace stylus guard and balance the tonearm with bias at a minimum. The arm should
move slowly and smoothly from the inner groove towards the armrest.

Add a tracking force of 0.1gram. The tonearm should now go slowly down and
outwards towards the armrest.

Balance the tonearm again and set the tracking force to 0.1gram. Now the tonearm should
move slowly up and out towards armrest.

If the tonearm does not behave in this way, repeat tests before consulting your
dealer.

Note: Ensure that tube movement is unobstructed by the cueing device.