Problems:

Platter not rotating:

Power supply- check if the red LED is on
-check selector to 33 rpm
- check connection cables from PS to motor
Consult dealer or qualified electrician.

Very slow start:
Only one motor is connected or one output channel of the PS has failed. Remove the platter
and belts and check that the motor pulleys are rotating. If only one motor pulley rotates,
disconnect the mains and connecting cables from the PS and reconnect the non- rotating
motor to the output of the second motor to check is there is a motor failure or a failure of
the PS.

Transportation:
For short distances dismantle the platter, remove belts and disconnect all cables. The base
with the subplatter can be transported as one, providing that it will not be tilted, as this may
cause oil leakage.
All parts are heavy, however, and can be easily damaged by sliding around a transport
vehicle. Repacking in original cutouts and boxes is , therefore, recommended.