SECTION VII: ELECTRICAL CONNECTIONS

WARNING

Turn off or disconnect the electrical power supply to the water heater before servicing. Label all wires

prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous

operation. Verify proper operation after servicing.
All electrical wiring must be installed and grounded in accordance with local codes, or in the absence of

local codes, the National Electrical Code, ANSI/NFPA 70 and/or CSA C22.2 Electrical Code.

The water heater must be wired to a 120 VAC, 60 Hz, 15A power supply. The water heater should be

connected to a GFI outlet and wired on a separate circuit and breaker. If a flexible line cord and plug is

permitted by local code, then provide a three wire GFI grounding type receptacle within reach of the

control box. Provide a grounded line cord and connect to the black and white power supply and green

ground screw. A strain relief will be required for the line cord. Do not plug the line cord into a receptacle

that can have the power supply interrupted by a switch that is used to control lights or another appliance.

If wiring in conduit is required, install an electrical conduit connector. A disconnect switch should be

provided near the water heater for servicing. Connect the wires exactly as shown in the wiring diagram of

this manual and on the inside cover panel. The black wire is the hot leg; the white wire is neutral. A

green screw is provided in the junction box for the green wire ground connection.

CAUTION

Do not energize the electric circuit before the water heater tank is filled with water.

21