LAARS IGE-199C - Installation Manual User Manual

Page 6

Advertising
background image

EVERHOT

® IGE Model Series Dimensions



Dimensions (Inches)

Height:

23 5/8”

(60.0 cm)

Width:

13 3⁄4”

(34.9 cm)

Depth:

8 7/8”

(22.6 cm)

Clearances from Combustible

Materials:

Top of water heater: 12” (30.5 cm), Front: 24” (61 cm), Sides: 6”

(15.2 cm), Back: 0”, Ground: 12 (30.5 cm)”

Maximum/Minimum Gas Input

Rating, Btu/hr.

199,000 maximum / 15,000 minimum for both Natural and L.P.

Gases.

Thermal Efficiency Rating

84%

Minimum/Maximum Gas Supply

Pressures:

Natural Gas: Minimum: 6.0” w.c., Maximum: 10.5” w.c.

Propane Gas: Minimum: 10.0” w.c., Maximum: 13.5” w.c.

Manifold Gas Pressure

Natural Gas: 3.4” w.c. Maximum input, 0.6” Minimum input

L.P. Gas: 5.1” w.c. Maximum input, 0.9” Minimum input

Venting System

Forced Combustion, external vent, For Outdoor Installation Only.

Setpoint Temperature (Without

remote temperature control)

140°F Commercial models, 120°F Residential models

Temperature setting range with

included Remote Temperature

Control

98-160°F, Residential models, 98-185°F Commercial models with

digital remote temperature control installed

Recommended Minimum water

supply pressure

20 PSI (50-80 PSI for maximum performance)

Maximum Water Supply

Pressure

150 PSI

Electrical Rating

120 volts, 60 Hz,

Normal operation: 63 watts, Anti-frost protection (when required):

84 watts

Electrical Consumption
Ignition System

Direct Spark Ignition

Water flow sensor, microprocessor controlled water flow solenoid,

bypass solenoid

Water Flow Control
Weight

46 Lbs. (20.9 kg)

6

Advertising
This manual is related to the following products: