°F

Set Temperature

Main Controller

239-44509-00

In Use

Priority

endless hot water system

CAUTION: Hotter water increases the risk
of scald injury. Before changing temperature
setting, see instruction manual.

Control for Commercial Models (Fig. 7)

Remote Temperature Control Installation:

Follow the same control installation procedure as outlined under “Temperature Control Installation” for

residential models.

WARNING

Do not attempt to connect the remote controls with the power on to the water heater. There are 120 volt

terminals and wiring next to the remote control connections inside the unit. All servicing and wiring must

be performed by a qualified installer.

Fig. 8 Control Wiring Connections Inside Water Heater

INITIAL OPERATION AND TESTING OF CONTROLS (INSTALLER ONLY)

1. Turn on power to the water heater and fully open a hot water tap.

2. Check the operation of the water heater. Check the operation of the remote temperature

control(s). Check the operation of the power failure protection system (drain solenoids).

3. Explain the proper operation of the new Laars EVERHOT® water heater to the

customer.

27