MT2P Pool Heater

Page 3

SECTION 1.

General Information

In the Commonwealth of Massachusetts, this

appliance must be installed by a licensed plumber or

gas fitter.

WARNING

The MT2P pool heater

must be installed in

accordance with the procedures detailed in this

manual, or the Laars Heating Systems warranty

may be voided. The installation must conform to the

requirements of the local jurisdiction having authority,

and, in the United States, to the latest edition of the

National Fuel Gas Code, ANSI Z223.1/NFPA54. In

Canada, the installation must conform to the latest

edition of CAN/CGA-B149.1, Natural Gas Installation

Code or CAN/CGA-B149.2, Propane Gas Installation

Code, and/or local codes. Where required by the

authority having jurisdiction, the installation of

MT2P appliances must conform to the Standard for

Controls and Safety Devices for Automatically Fired

Boilers, ANSI/ASME CSD-1. Any modifications to

the boiler, its gas controls, or wiring may void the

warranty. If field conditions require modifications,

consult the factory representative before initiating

such modifications.

1.1 Introduction

This manual provides information necessary for

the installation, operation, and maintenance of Laars

Heating Systems MT2P copper tube pool heaters. Read

it carefully before installation.

All application and installation procedures

should be reviewed completely before proceeding with

the installation. Consult the Laars Heating Systems

factory, or local factory representative, with any issues

or questions regarding this equipment. Experience

has shown that most operating issues are caused by

improper installation.

The MT2P appliance is protected against over

pressurization. A pressure relief valve is fitted to all

appliances. It is installed on the outlet header, at the

water outlet of the appliance.

IMPORTANT: The inlet gas pressure to the appliance

must not exceed 13" W.C. (3.2kPa).

All installations must be made in accordance

with the 1). American National Standard Z223.1/

NFPA54-Latest Edition “National Fuel Gas Code”

or 2). CAN/CGA 1-B149 “Installation Codes for Gas

Burning Appliances and Equipment” and with the

requirement of the local utility or other authorities

having jurisdiction. Such applicable requirements take

precedence over the general instructions contained

herein.

All electrical wiring is to be done in accordance

with the local codes, or in the absence of local codes,

with: 1). The National Electrical Code ANSI/NFPA No.

70-latest Edition, or 2). CSA STD. C22.1 “Canadian

Electrical Code - Part 1”. This appliance must be

electrically grounded in accordance with these codes.

1.2 Model Identification

Consult the rating plate on the unit. The following

information describes the model number structure.

Model Character Designation

1-3 Model Series Designation

M T 2 = Mighty Therm

2

4 Usage

P = Pool Heater

5-8 Size

0 5 0 0 = 500,000 BTU/h input

0 7 5 0 = 750,000 BTU/h input

1 0 0 0 = 999,000 BTU/h input

1 2 5 0 = 1,250,000 BTU/h input

1 5 0 0 = 1,500,000 BTU/h input

1 7 5 0 = 1,750,000 BTU/h input

2 0 0 0 = 1,999,000 BTU/h input

9 Fuel

N = Natural Gas

P = Liquid Propane

10 Altitude

A = 0-10,000 feet

11 Location

C = Indoor and Outdoor

12 Firing Mode

C = On-off

13 Revision

1 = First version

1

2

3

4

5

6 7 8

9

10

11

12

13

14

15

16

M T

2

P

A

C

C

1

SERIES

M T 2

USAGE

P

SIZE

0 5 0 0

0 7 5 0

1 0 0 0

1 2 5 0

1 5 0 0

1 7 5 0

2 0 0 0

FUEL

N
P

ALTITUDE

A

FIRING

MODE

C (ON/OFF)

LOCATION

C

REVISION

1

HEAT

EXCHANGER

B
C
N
P

OPTIONS

CODE

X

J

PUMP

OPTIONS

N
B

Advertising