PIPE LENGTHS

"H"

One Pipe Gravity System

3/8" O.D.

1/2" O.D.

ft

ft

ft

0

33

65

3

65

130

5

130

260

195

325

PIPE LENGTHS

"H"

Two Pipe Lift System

3/8" O.D.

1/2" O.D.

ft

ft

ft

0

115

330

100

330

3

80

330

5

65

295

50

230

25

100

11

20

65

Figure 5. One-Pipe System.

Figure 6. Two-Pipe System.

WARNING

The height should not exceed 13 feet.

WARNING

The vacuum must not excedd 11.44 HG (11.44
inches of Mercury). Burner is shipped from the
factory set up for two pipe system.

Important

An external filter must be placed in the fuel line
between the fuel tank and the burner pump.

Air Vent

Fill Pipe

1¼" min

Valve

Oil Tank

Filter

Burner

"P"

Boiler

Air Vent 1¼" min.

Fill Pipe

Valve

Filter

Burner

Boiler

Oil Tank

"H"

"H"

OUT OF

PRODUCTION