LAARS Mighty-Stack TL80-199 - Installation, Operation and Maintenance Instructions User Manual

Page 5

Advertising
background image

Mighty Stack Water Heater

Page 5

Figure 4. Installation in Closet.

water will not damage areas below the appliance.

If a suitable location can not be found, install a

drain pan under the appliance. Make sure the

drain pan is properly piped to an adequate drain.

2.

Place the water heater as close as possible to the

vent or chimney.

3.

For minimum clearances around the water heater,

refer to Table 2. Maintain the minimum distances

from all combustible surfaces (see Figure 4). The

unit can be installed in a closet. Pay special

attention to the air supply opening to the closet.

It is recommended that at least 12 inches

(305mm) is allowed around the entire unit for

maintenance, inspection, and plumbing access.

Left

Right

Side

Side

Rear

Front

Flue*

Top

inches

6

6

2

2

6

18

mm

152

152

51

51

152

457

*One inch (25 mm) clearance using type B double wall vent pipe

when vented vertically.

Table 2. Minimum Clearances from

Combustible Surfaces.

4.

This product may be installed on combustible

flooring. Do not install directly on carpeting.

5.

Be sure that the parts in the gas ignition system

are protected from water when the water heater is

operating or being serviced. Arrange water lines

in the area so that water cannot drip or spray

onto the water heater.

6.

If the product is to be installed in a location

where vibration or tipping is a concern, the unit

may be secured to a fixed vertical surface. The

TL80 is equipped with slots in the cabinet that

can accommodate a strap up to 1½" wide. To

secure the unit to a wall, place a strap around the

tank (not the tank enclosure), as shown in Figure

3. Allow the strap to pass through the slots

provided in the cabinet. Secure the strap as

necessary to the wall.

1H. Gas Supply Piping

Please review these instructions before installing

the water heater.
1.

Check that the water heater is fitted for the

proper type of gas by checking the rating plate.

2.

Laars water heaters are normally equipped to

operate below a 2000 foot altitude. Water heaters

equipped to operate at higher altitudes have

appropriate information on the rating plate.

Figure 3. Strap Location.

3.

Use the figures in Table 3 to provide adequate gas

piping from the gas meter to the water heater.

4.

A sediment trap (drip leg) must be provided

ahead of the gas controls (see Figure 5). A

manual gas shutoff valve must also be provided

for service, convenience and safety. This should

be installed about 5 feet (1.5 m) above the floor.

Check the local codes.

5.

Turn off the water heater before you do any

pressure testing on the gas lines.