Ground Control 3.0 Service Manual

LCD Message

What's Happening?

What Should Be Done?

****ERROR****

Low Voltage

Battery voltage dropped below

10.8V.

Check wiring for loose connection.
Test battery voltage under load - charge or

replace.

****ERROR****

Out Of Stroke

Jack has reached maximum

stroke length and is unable to lift.

Check disposition of jacks. Relocate the

coach.

****ERROR****

External Sensor

Bad connection or wiring from

the controller to the rear sensor.

Replace or repair connection to rear

remote sensor.

****ERROR****

Jack Time Out

Time limit exceeded for the

requested auto operation.

Check disposition of jacks.

****ERROR****

Auto Level Fail

Unable to auto level due to

uneven ground.

Check disposition of jacks. Relocate the

coach.

Unable to auto level due to zero

point being set incorrectly.

Reset zero point.

****ERROR****

Bad Calibration

Sensor calibration values are out

of range.

Reset zero point.

****ERROR****

Internal Sensor

Internal sensor problem.

Replace controller.

**PANIC STOP**

Function Aborted

The user pressed a button on the

touch pad during an automatic

operation.

Restart automatic operation and then

refrain from pressing any buttons on the

touch pad.