Rev: 01.30.2015

Page 15

Ground Control 3.0 Service Manual

Fig. 23

7. Attach the replacement rear sensor (Fig. 23B) to the mounting plate (Fig. 23C) using two 3⁄8" hex head

self tapping screws (Fig. 23A). Orientation is imperative for the correct operation of the leveling system.

A

B

C

Fig. 24

8. Attach the mounting plate (Fig. 24B) and replacement sensor (Fig. 24C) assembly to the crossmember

(Fig. 24D) using two 3⁄8" hex head self tapping screws (Fig. 24A). Ensure that the plate is centered side

to side on the frame and that the sensor is oriented properly (Fig. 24).

A

B

C

D