Manual override for unidirectional power units – Lippert Components LCI Electronic/Hydraulic Leveling & Slideout User Manual
Page 18

Rev: 07.14.2014
Page 18
Untitled-1
Clockwise for manual override
Counter-clockwise for normal operation
Fig. 19 - Unidirectional
Fig. 20- Unidirectional
Manual Override for Unidirectional Power Units
In the event that the jacks or slideouts will not extend or retract, the valves can be manually overridden. THIS IS
IN AN EMERGENCY SITUATION ONLY! By using a hex wrench to turn the manual override clockwise on the valve
(Fig. 19), and a drill to operate the motor, the leveling jacks can then be retracted. Remember to turn the manual
override completely counterclockwise (Fig. 20) until it will no longer turn, to close the valve after the jacks or
slideouts have been completely extended or retracted.
1. Remove protective plastic cap (Fig. 22A).
2. Unplug connector from the directional valve (Fig. 21).
3. Manually open jack valves with a 5/32" hex wrench (Fig. 19).
4. Using a 1/2" nut driver, insert into auxiliary drive device, i.e. cordless or power drill.