Lippert Components LCI Electronic/Hydraulic Leveling & Slideout User Manual

Page 28

Advertising
background image

Rev: 07.14.2014

Page 28

Untitled-1

Slideout Adjustment

2"-3" Free Travel

Adjusting room so it seals in the "IN" position

1. Locate cylinder coming through the frame.
2. Run the room partially out.
3. Hold jam nut (Fig. 32A) in place with a wrench.
4. Adjust Nylock nut (Fig. 32C) towards the bracket if the room does not seal or adjust the Nylock nut (Fig.

32C) away from the bracket if the room is too tight and damages the fascia.

NOTE: Make small adjustments running the room in after each adjustment until proper seal is achieved.

Adjusting room so it seals in the "OUT" position

1. Locate actuator coming through the frame.
2. Extend room completely out.
3. Check the inside fascia and seal positioning.
4. Partially retract room.
5. Loosen Jam nut (Fig. 32A) from nut (Fig. 32B) and back off Jam nut (Fig. 32A) to give nut (Fig. 32B)

room for adjustment.

6. Adjust nut (Fig. 32B) away from the bracket if the room extends too far and damages the inside fascia

or adjust nut (Fig. 32B) towards the bracket if the room does not seal.

NOTE: Make small adjustments, running the room out after each adjustment until proper seal is achieved.

Tighten Jam nut (Fig. 32A) to nut (Fig. 32B).

Fig. 32

C

B

A

Advertising