BFC36 Balance Flue Heat-Circulating Fireplace

7412647

Positioning, Safety Strips,

Securing the Fireplace

Slide fireplace into position.
Lift the fireplace front slightly and slide the metal safety
strips under front bottom edge about 1¹⁄₂” (38mm), al-
lowing the remainder to extend in front of firebox. Over-
lap strips at least 1/2” (13mm) to provide a positive joint.
(Flat safety strips are packed with fireplace.) (Fig. 12)
Safety strips are used to ensure that any combustible
materials in front of the fireplace are protected even
though a non-combustible hearth extension is required.
If fireplace is to be elevated above the floor, a “Z”
shaped metal safety strip must be fabricated and used
to protect combustible surfaces in front of the fireplace.
This “Z” shaped safety strip is not provided but must be
fabricated of metal with each horizontal leg at least 1¹⁄₂”
(38mm) wide and equal in length to the metals strips
provided with the fireplace.
NOTE: Safety strips are not required over non-com-
bustible floors where all supports at the base of the
fireplace are noncombustible.
Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and
secure it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 13.

FPC549a

BFC

Nail flange/standoff

circulating models

8/21/00 djt

Nail Top

Standoffs

Nail Side-

Nailing

Flanges

FPC549a

Fig. 13 Fasten fireplace in position.

WF557

BR

11/10/97

Metal Safety Strips

(1,2 or 3 pcs.)

“Z” Safety

Strip

(not sup-

plied)

Fire-

place

Plat-

form

Hearth Ext.

¹⁄₂

” (13mm)

Min. Overlap

1¹⁄₂”

(38mm)

FP557b

Fig. 12 Safety strip installation.