Chapter 10. Programming Guidelines
The advanced commands allow users to programmatically change the GNAV540 settings. This section of the manual
documents all of the settings and options contained under the Unit Configuration tab within NAV‐VIEW 2.2. Using
these advanced commands, the settings of a GNAV540 unit can be modified without NAV‐VIEW 2.2.
Configuration Fields
Configuration fields determine various behaviors of the unit that can be modified by the user. These include settings
like baud rate, packet output rate and type, algorithm type, etc. These fields are stored in EEPROM and loaded on
power up. These fields can be read from the EEPROM using the RF command. These fields can be written to the
EEPROM affecting the default power up behavior using the WF command.
The current value of these fields (which may be different from the value stored in the EEPROM) can also be accessed
using the GF command. All of these fields can also be modified immediately for the duration of the current power
cycle using the SF command. The unit will always power up in the configuration stored in the EEPROM.
Configuration fields can only be set or written with valid data from Table 55 below.
Table 55 Configuration Fields
index Configuration fields
Field ID
Valid Values
Description
1
packet rate divider
0x0001
0,1,2,4,
20, 25,
5,10,
50
quiet, 100Hz, 50Hz, 25Hz, 20
4Hz, 2Hz
Hz, 10Hz, 5Hz,
2
Serial Port A BAUD rate
0x0002
0,1,2,3
9600, 19200, 38400, 57600
3
Continuous packet type
0x0003
Any output
acket type
p
Not all output packets available for all
products. See detailed field descriptions
.
below
4
Reserved
0x0004
N/A
5
Reserved
0x0005
N/A
6
Reserved
0x0006
N/A
7
Orientation
0x0007
See below
Determin
and dow
facing sid
e forward, rightward,
nward
es
8
User Behavior Switches
0x0008
Any
Refer to User Behavior Switches, page 88
9
X Hard Iron Bias
0x0009
Any
I2 scaled from (‐1,1)
10
Y Hard Iron Bias
0x000A
Any
I2 scaled from (‐1,1)
11
Soft Iron Scale Ratio
0x000B
Any
U2 scaled from (0,2)
12
Heading Track Offset
0x000C
Any
Heading‐Track Offset to use in NAV filter track
update mode.
13
Turn Switch Threshold
0x000D
73‐65535
. ‐3 0 °/s)
(0 4 6
Sets yaw rate above which tilt feedback is
attenuated.
14
ngle
Soft Iron A
0x000E
(‐π π)
Angle of major axis of the ellipse generated by
60 degree swing in radian
3
15
reserved
0x000F
16
hardwareStatusEnable
0x0010
Any
Bit mask of enabled hardware status signals