NORAC UC4+BC+JD7 User Manual

Page 14

Advertising
background image

12

Exhaust clamps (B16) can be

used if mounting the sensor
brackets to a portion of the

boom with round tubing.

Figure 6: Low Profile Bracket

Mounted with Exhaust Clamps

General Mounting Rules for Low
Profile Brackets:
a) Minimize the distance between the bolts

to prevent bending the bracket and
prevent the bracket from loosening
over time.

b) Ensure the bracket is mounted tight

against the bottom of the boom,
minimizing the distance between the
boom structure and the angled flange.

Figure 7: Bracket Mounting Guidelines

General Mounting Rules for UC4+
Ultrasonic Sensors:

a) In its lowest position, the sensor must

be 9 inches (23 cm) or more from the
ground.

b) Ensure that there are no obstructions

within a 12-inch diameter circle
projected directly below the center of

the sensor.

c) The sensor should be approximately

vertical at normal operating heights.

Figure 8: Sensor Mounting Guidelines


Front

Advertising