6 hydraulic installation, 1 valve assembly – NORAC UC4+BC+JD7 User Manual

Page 21

Advertising
background image

19

4.6 H

YDRAULIC

I

NSTALLATION

WARNING!

The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.

When changing the boom hydraulic
hoses leave the booms in
TRANSPORT POSITION.

IMPORTANT:

Component failure due to oil
contamination is not covered under
the UC4+ Spray Height Control
system warranty. It is recommended
that a qualified technician does the
hydraulic installation.

4.6.1 Valve Assembly

1. On a clean surface remove all plastic

plugs from the NORAC hydraulic Valve
(V01) (Figure 20).

2. Install the 6MB-6MOR fittings (F05) on

the "P" and "T" ports and tighten to 18

ft-lbs.

3. Install the 4MOR-4MB (F06) into the

"S" port and tighten to 11 ft-lbs.

Figure 20: NORAC Valve Block

4. Install two orifices (F08) into the "B"

ports with the notch facing outward
as shown in Figure 21.

5. Install the remaining orifices (F08) into

the "A" ports with the notch facing
inward
as shown in Figure 21.

6. Install the 6MB-4MOR fittings (F07)

into the "A" and "B" ports and tighten to
18 ft-lbs.

Figure 21: Valve Block Assembly

If the Roll Control Option is also

being installed the 3

rd

station

valve can be assembled before

mounting the valve. See the Roll
Control Option Installation
Manual that came with your kit.

4. Remove the plug from the Sense Line

Bleed port. Location is shown in
Figure 22. Gently tap the plug with a
hammer to loosen it before attempting
to remove it.

5. Remove the Sense Line Bleed Orifice

and discard. Figure 22. Install the
setscrew (F11) into the Sense Line
Bleed Orifice location. Ensure the
setscrew is threaded entirely into the

Advertising