If the engine fails to start, Valve adjusting – O.S. Engines FS-40S-CX User Manual

Page 18

Advertising
background image

Note:
Valve clearances of all O.S. four-stroke-
cycle engines must be checked and reset
ONLY WHEN THE ENGINE IS COLD.
Procedure is as follows.

• Feeler gauge 0.04mm

ALL O.S. four-stroke engines have their
valve(tappet) clearances correctly set before
they leave the factory. However, if, after many
hours of running time have been logged, a loss
of power is detected, or if the engine has to be
disassembled or repaired as a result of an
accident, valve clearances should be checked
and readjusted, as necessary. O.S. Valve
Adjusting Tool Kit is available as optional
accessory.

VALVE ADJUSTING

The kit comes in a plastic case and includes:
(Code No.72200060)

• Feeler gauge 0.1mm

• Hex. key 1.5mm

• Wrench 5mm

For 40S-CX

IF THE ENGINE FAILS TO START

Check the following:

Glowplug battery discharged or glowplug
defunct.

Fuel not reaching carburettor.

Engine flooded. Do not over-prime. (This

could also cause hydraulic lock and damage
the engine on application of the electric
starter.) Remove glowplug, close needle-
valve and apply starter to pump out surplus
fuel. (Cover the plug hole with a foided cloth,
so that fuel cannot spiash into your face.)

17

Advertising