BAD BOY

®

SPOT LUMINAIRE USER MANUAL

19

Step

6. Connect power and data cables according to

"Connecting Power and Data"

on page 23.

Figure 2-5: Standard Hanging Configuration and Dimensions

(762 mm)

30"

15.6"

(396mm)

(343 mm)

13.5"

39.125"

(994 mm)

Two (2) Safety Cables MUST be used
for all hanging installations and may
be required by local codes.

Safety cables and input
pigtail cable must be dressed
to avoid interference with
luminaire motion.

Square tube or round
pipe. Minimum outside
dimension for pipe or
tube is 1 inch (2.54 cm).
Maximum outside
dimension is 2 inches
(5.08 cm)

POSITIONING

:

Can be mounted in any orientation.
SPACING

:

Hangs on 30 inch (762 mm) centers.
WEIGHT

:

167 lbs (75.8 kg) - includes clamps and rails